The procedure of thermal treatment of residues of previously processedmunicipal waste (light fraction – LF) and dehydrated sludge (SWTP - sludge from wastewater treatment plants) consists of the following steps:

The heating system belongs to the group of modular combustion systems with the grate. The combustion facility consists of a primary (from 650 to 850°C) and secondary (up to 1,100°C) chamber. A high degree of completeness of combustion is identified with a minimum content of CO in the flue gas, which is constantly under 30mg/m3.
The following waste is generated in the thermal treatment procedure: